Scytek electronic Galaxy 2100RS-DBP Manual

Busca en linea o descarga Manual para Alarma de carro Scytek electronic Galaxy 2100RS-DBP. Scytek electronic Galaxy 2100RS-DBP Product manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - SERIES-DBP

GALAXY5000RS/2000RSSERIES-DBPDATA BUS PORTVEHICLE SECURITY SYSTEMWITH REMOTE START PRODUCT MANUAL

Pagina 2 - System Contents:

Button 1Button 2Button 3Button 4Button 511/16 3:10PBattery statuswakeupalarmenabledautostartenableddate/engine run timertimeOptional 2-way Co

Pagina 3 - Transmitters

Press and hold Buttons 2 and 3 until pager program features are displayed.Select pager setting by pressing buttons 1 or 2 to highlight the pager. Pres

Pagina 4 - Battery Replacement

Use buttons 1 & 2 to highlight the time parameter you wish to change, use buttons 3 & 4 to scroll up ordown to chage the time. Save the change

Pagina 5

Return to Previous ScreenSelect Previous Screen by pressing buttons 1 or 2 to highlight the feature. Press button 3 to select it.Press and hold Button

Pagina 6 - Setting The Alarm Clock

Setting AutoStart Cold Temperature ThresholdSelect Cold Temp start setting by pressing buttons 1 or 2 to highlight the feature. Press button 3 to sel

Pagina 7 - LCD Backlight

Select Clock Sync setting by pressing buttons 1 or 2 to highlight the pager. Press button 3 to select thepager.Pager Clock SyncThis feature synchroniz

Pagina 8

Use buttons 1 & 2 to highlight Set Time press button 3.The security system responce.Start Time 2This feature sets the system Autostart 2 time.Sele

Pagina 9

Pressing and holding transmitter button 5 will scroll through several transmitter programmableoptions - TEMPERATURE, ENABLE COLD START, ENABLE HOT STA

Pagina 10 - System Confirmation

Transmitter LockoutPress and hold buttons 2 & 4 simultanously for 3 seconds tolockout the transmitter against accidental transmission.Release Tran

Pagina 11 - PARAMETERS

PPaaggeerr SSttaattuuss DDiissppllaayyTime: time of day clockDate/Engine Run Timer: date, or engine run minutetimer if remote start activated (2

Pagina 12 - Selecting Sound/Vibration

The ScyTek Galaxy 5000RS-DBP Series is a Combination Vehicle Security and Remote StartingSystem, Galaxy 2000RS-DBP Series is a Remote Starting with

Pagina 13 - Passive Arm Enable/Disable

Remote Arming/LockingThe system monitors 5 independent areas (zones) while armed: doors, hood/ trunk, shock sensor, optionalsensor input, and the netw

Pagina 14

Tamper AlertIf the system was triggered while away, the LED will flash to indicate which zone triggered the system afterdisarming and turning the igni

Pagina 15 - Start Time 1

Panic ModeIn the event of an emergency, the transmitter’s remote Panic feature can be used to instantly trigger thealarm/panic feature.To activate the

Pagina 16 - Recall Alarm History

3. Press the valet switch 4 times.· The siren will chirp each time the valet switch is pressed.4. Within 5 seconds, press Button 3 on the transmitter.

Pagina 17

Remote StartingTo Remote Start the System:1. Be sure the system is not in Valet Mode.2. Press and hold Button 4 for three seconds.· The parking ligh

Pagina 18 - FUNCTION

Automatic Start ModeAutomatic Start feature has three modes that will start the vehicle every one or two hourswithin a 24 hour period.1. Timer Only M

Pagina 19

Model: Galaxy 5000RS-DBP-M 1- Tach wire must be connected , The system must learn RPM.2- Hand brake must be connected.3- Door trigger must be connecte

Pagina 20 - Tamper Alert

Extended FeaturesIgnition Door LockingFor added safety, the Ignition Door Locking feature allows vehicles equipped with power door lock systemsto aut

Pagina 21 - Passive Arming

1. Thoroughly read and become familiar with the installation instructions before beginning the installation.2. Review system contents:Main Unit 1 or

Pagina 22 - * Emergency Override

Mounting the Control UnitThe control unit must only be mounted in the interior of the vehicle. Do not mount the main unit inthe engine compartment.

Pagina 23 - DRIVER CALLING/PAGE FEATURE

Standard Remote Transmitter DescriptionDepending on the model chosen, the Galaxy 5000RS-DBP Series will be supplied with one or two T5 orT5-SP 5-butt

Pagina 24 - Features

System Wiring6-Pin Starter HarnessPin 1 RED WIRE A: Main Power Input A (+). Connect to the battery or constant power wire at the ignitionswitch with

Pagina 25 - Turbo Timer Feature

Pin 11 VIOLET WIRE: Positive Door Input (+). Connect to the door switch circuit wire that shows +12Vwhen the door is open. This type of door circuit

Pagina 26 - Shut Down

2-Pin White Connector: Located on the side of the main module.· Green WIRE - Parking Brake Input (-) For Manual Transmission and/or vehicles equipped

Pagina 27 - Extended

Entering System ProgrammingThis system is compatible with both the LCD two way transmitter or the standard transmitter, all systemprogramming can be

Pagina 28 - Installation

the ignition is turned off. The Ignition Door Locking feature may be programmed to unlock all doors orthe driver’s door only. If driver’s door only i

Pagina 29 - Mounting the Shock Sensor

by programming the system for double unlock pulse. 7. Door Lock Pulse Length. Selects between a 1, 3 or 0.1 seconds output for door locking andunlocki

Pagina 30 - 20-Pin Main Harness

16. Auxiliary 3 Output Mode. Selects between Channel 3, Factory Rearm output, or third Ignitionouput.17. Lock After Start. When selected, the doors w

Pagina 31 - Plug-in Connectors

28. Siren Mode. Selects standard siren (defualt) or MP Player Siren. 29. Turbo Timer. When enabled, if the emergency brake has been applied Ignition

Pagina 32 - Settings

Relay DiagramsPositive Dome Light ActivationNegative Dome Light ActivationPositive Horn Honk Negative Horn HonkStarter Defeat/Anti-GrindNegative Glow

Pagina 33 - Programming

Negative TriggerReverse Polarity VacuumAdding ActuatorsFollow the diagrams below for connecting basic door lock systems. For Two Stage door locksyste

Pagina 34 - Programming Branch Table

Adding/Replacing Standard Remote Transmitters To replace lost or stolen transmitters or to add additional transmitters into the system, have all desi

Pagina 35

Two Stage Door Lock DiagramsTwo Stage Negative TriggerTwo Stage Positive TriggerThe Galaxy 5000RS-DBP Series is equipped with a dedicated Passenge

Pagina 36

Two Stage Door Lock Diagrams cont’dTwo Stage Reverse PolarityTwo Stage Adding Actuators

Pagina 37

FCC ID: OARRXAM2000This device complies with Part 15 of FCC Rules.Operation is subject to the following two conditions:1) This device may not cause ha

Pagina 38 - Diagrams

Starter DiagnosticsStarter doesn’t start and parking lights flash:3 Times - Engine RPM not detected (check tach wire and/or perform tach learn proce

Pagina 39

Shock Sensor Adjustment:Clock wise increases sensitivity Shock Sensor Adjustment

Pagina 40 - Door Lock Inverter Blue Wire

Wiring DiagramScyNetBlue Aux Start (-) / Turbo Timer CancelGreen Emergency brake(-)AntennaShock Sensor PortLED PortValet Switch PortDoor Lock PortMai

Pagina 41 - Two Stage Adding Actuators

2-way LCD Remote Transmitter DescriptionDepending on the model chosen, the Galaxy 5000RS-DBP-2W Series will be supplied with one or two 2-way LCD Remo

Pagina 42

3. Press and release Button 1 on the first transmitter then on the second transmitter.· The siren/horn will chirp/honk once for every transmitter lea

Pagina 43 - Starter Diagnostics

To set the daily start feature:1. Press and hold Buttons 2 and 3 until the remote beeps four times.· The fan and clock will be shown indicating daily

Pagina 44

CHP Set the siren/horn confirmation chirps/honks ON or OFF:1. Press and hold Button 5 until the display shows CHP.·The transmitter will beep three tim

Comentarios a estos manuales